Lightning Protection
Design, installation and care of lightning protection systems that keep buildings and the people in them safe.
- Lightning protection design
- New system installation
- System alterations and extensions
- Inspection and testing
Fabier Building Performance
Nine specialist service lines under one standard: protection, compliance, engineering, maintenance and facilities management, delivered with clarity, care and technical discipline.
People. Places. Performance.
Fabier exists to make buildings safer, better maintained and easier to manage. We combine specialist technical delivery with a clear, accountable service built around the people responsible for property.
Accredited
CHAS · Constructionline · SSIP
Standards
BS EN IEC 62305 series · BS EN 62561 · BS 7430:2026 · BS 7671:2018+A4:2026
Quotations
We aim to return straightforward quotations within 1 working day. More complex designs and multi service requirements may require additional review. We will confirm timescales from the outset.
What we do
Design, installation and care of lightning protection systems that keep buildings and the people in them safe.
Annual testing, certificates, remedials and test and maintenance agreements.
Earthing systems designed, installed and verified with the same discipline as our protection work.
Planned maintenance and statutory checks that keep heating, ventilation and cooling performing.
Statutory testing, certification and a single record of where every building stands.
Surveys, BS EN 62305-2 risk assessments, design and technical submissions.
Planned building maintenance on one programme, with one point of accountability.
People, places and performance managed together across a building or a portfolio.
Why Fabier
Specialist knowledge delivered in plain language, so you always know where your building stands.
Practical recommendations and records you can rely on — for insurers, auditors and your own peace of mind.
The same care across site work, reporting and client service, on every building, every time.
We work for lasting building performance, not one-off transactions.
Projects
FABIER PROJECT
Student accommodation · 2025 to 2026
Design, supply, installation, testing and certification of six separate Class IV lightning protection systems to two accommodation blocks and four terraces, plus a UKPN substation earth.
Structures protected
Contract value
Protection class
Read case study
FABIER PROJECT
Residential · 2026
Level IV protection to two new buildings using the structural frame as down conductors and the pile foundations as the earth electrode, with a 20 x 20 m aluminium mesh and bonded roof handrails.
Down conductor positions
Dedicated earth rods
Site attendances
Read case study
FABIER PROJECT
Sports · 2023
Lightning protection to a new steel framed training ground building using 13 structural columns as down conductors and 13 pile caps as the earth termination, with an aluminium tape air termination at roof level.
Columns as down conductors
Pile cap earth connections
External down tapes
Read case study
How we work
Survey first. We record what is actually there, what the standard requires and what the building already offers before anything is priced.
The compliant scope is priced clearly, with genuine options listed separately, so nobody buys copper they do not need.
The people who design the work supervise it, and the people who install it come back to test it. One team, one standard.
Certificates, readings, drawings and next due dates held digitally across a building or a whole portfolio.
Insights
Risk Assessment
The risk assessment explained for building owners: the four losses, what drives the number, and why most buildings need a Class III system or nothing at all.
FABIER Insights · 4 min read
Cost
Consultants over provide. How Fabier prices what BS EN 62305-3 needs and lists the extras as options, so the client sees the real cost of copper and tighter down conductor centres.
FABIER Insights · 4 min read
Design
Metal roofs, structural steel, rebar and piles as air termination, down conductors and earth electrodes, and when a dedicated system is the honest answer.
FABIER Insights · 4 min read